Technical Specifications: 1.Temperature measuring range: -30℃~+60℃ (Internal sensor) 2.for optional external sensor: -40℃~+85 ℃ (optional external sensor) 3.Temperature Accuracy: ±0.5 (-20℃/+40℃) ±1.0(other range) 4.Temperature Resolution: 0.1 ℃ 5.Data Storage capacity: 16000 points readings 6.Record interval: 10s~24hour adjustable 7.Stop Mode: Button, software or stop when full 8.Startup Mode: Button 9.Validation Certification: Hardcopy 10.Certifications: EN12830, CE, RoHS 11.Connection Interface: Mini USB 12.Alam Configuration: Optional, only 2 points 13.Software: ElitechLog Win or Mac(latest version) 14.Report Generation:PDF&Excel report by Elitech software 15.Power supply: 1years^1/CR2450 battery cell( included) 16.Battery life: in normal temperature, if the record interval sets as 15 minutes, it could be used
above one year. 17.Item Size: approx. 84 (L) x 44 (W) x 20 (H) mm (3.3 x 1.73 x 0.79 inch) 18.Item Net Weight: 34 g
Important:
1. Please store the logger in indoor environment. 2. Do not use the logger in corrosive liquid or excessive heat environment. 3. If this is the first time you use the logger, it is suggested to connect the logger to a computer to
sync the time. 4.Please dispose or handle the waste logger properly by local legislation.
Package include: 1 x Data Logger 1 x External Sensor 1 x USB Cable 1 x Instruction Manual



Recording Options:Multi-Use
Temperature Range:-30℃ to 60℃(internal sensor) -40℃to 85℃(optional extemal sensor)
Humidity Range:10%-99%
Accuracy:±0.5(-20℃/ +40℃);±1.0(other range) ±3%RH(25℃,20%RH to 90%RH),±5%RH(other range)
Temperature Resolution:0.1℃,0.1%RH
Battery:CR2450 button cell( included)
Recording interval:15 minutes(standard,others on request)
Stop Mode:Button,software or stop when full
Demensions:84mmx44mmx20mm(LxWxH)
Weight:35g
Start/Stop Logger:
1.Connect the logger to a computer to sync the logger time or configure parameters as needed.
2.Press and hold Button to start the logger until shows.The logger starts logging.
3.Press and release Button to shift between display interfaces.
4.Press and hold Button to stop the logger until shows.The logger stops logging.
Please note all the recorded data cannot be changed for security reasons.
Package: 1 x Data Logger 1 x External Sensor 1 x USB Cable 1 x Instruction Manual





Specifications:
*Temperature range: -30 °C~+70 °C
*Temperature Accuracy:±0.5(-20℃/ +40℃);±1.0(other range)
*Temperature Resolution:0.1 °C
*Date Storage Capacity:32000 readings
*Shelf Life/Battery:Six months/CR2032 button cell (included)
*Recording Interval:10s-24hour adjustable
*Protection Class:IP67
*Dimensions:80*33*14mm
*Weight:35g
Important!
Please store the logger in indoor environment.
Do not use the logger in corrosive liquid or excessive heat environment.
If this is the first time you use the logger,it is suggested to connect the logger to a computer
to sync the time.
Please dispose or handle the waste logger properly by local legislation.




Precautions:
*Please read the manual carefully before using the logger.
*To synchronize system time, it is recommended to connect the logger to a computer for parameter configuration before it is used for the first time.
*The LCD screen will be off after 15 seconds of inactivity.Press the left key to lighten it.
*Never dismantle the battery.Do not remove it if the logger is running.
*Replace the battery in time for long distance transport if its power remains half.
*Replace old battery with a new CR2032 button cell with the negative inward.
Specifications:
Temperature range:-30 ° C ~ 70 ° C
Temperature accuracy:±0.5(-20℃/+40℃);±1.0(other range)
Temperature Resolution:0.1° C
Date Storage Capacity:32000 readings
Shelf Life/Battery:1 years/CR2032 button cell ( included)
Recording Interval:2 minutes (standard)
Protection Class:IP67
Dimensions:80*25*12mm
Weight:35g
Connection Interface:USB 2.0,A-Type






Technical parameters:
1. Temperature measuring range:-40℃~85℃
2. Temperature accuracy:±0.5℃(-20℃~40℃);±1℃(others)
3. Humidity range:10%~99%
4. Humidity accuracy;±3%RH(25C,20%~90%RH);±5%RH(others)
5. Resolution: temperature 0.1C,humidity 0.1%RH
6. Record capacity:16000 points(MAX) 7. Dimension;118 (length)*61.5(width)*19(height)(mm) 8. Record interval:10 sec~24 hour continuously set 9. Data interface:USB 10. Power supply:single-use 3.6V lithium battery(included) or powered via USB 11. Battery life:two years at room temperature with 15 minute record interval and buzzer alarm disabled 12. Ambient temperature:-30℃~70℃.At low temperature environment,the LCD screen displays normal record but a little slowly.It will display data normally when the ambient temperature returns to normal. 13. Software download: www.elitechlog.com/softwares
Use the data logger for the first time: 1. Install the data management software for RC-61 data logger (referred to as the data management software).Insert the data logger to a computer USB port and install the setup software according to the prompt information. 2. Open the software, and the data logger will automatically upload information after connected to the computer. 3.Click the icon "set parameter"and set the parameters according to your desire. Click "save parameter"to exit from the setting interface. 4.Press and hold the left button for more than 4 seconds,the symbol lights to start recording.Click the icon "upload data"to view the data. 5. Log out the data management software.